Description
TECTYL 802A is a lubricating oil and corrosion
preventive compound. TECTYL 802A is approved
under Military Specifications MIL-PRF-3150C, Amd. 2,
(superceded by Mil-Pref-31500) QPL Reference
Number L-6564, and MIL-P-116J, Type P-7. It is
used to protect transportation equipment assemblies.
Tectyl 802A Laboratory Data Tectyl 511M Typical Properties
Tectyl 802A Flash, PMCC*, Minimum 330F
Tectyl 802A Density, Weight/Gallon @ 77F (25C) 7.64 lbs./gallon
Tectyl 802A API Gravity @ 60/60 22.5 0.5
Tectyl 802A Specific Gravity @ 60F (15.6C) 0.93
Tectyl 802A Recommended Dry Film Thickness over Metal Profile 0.4 mils
Tectyl 802A Theoretical Coverage @ Recommended DFT 3,890 sq. ft./gallon
Tectyl 802A Viscosity @ 100F (37.8C), SUS 545
Tectyl 802A Pour Point 0F
Tectyl 802A Non-Volatile % by Weight 97.5 2
Tectyl 802A Non-Volatile % by Volume 97 1
Volatile Organic Content (VOC), Typical CALCULATED 0.19 lbs./gallon
Volatile Organic Content (VOC), Actual EXEMPTED <0.1 lbs./gallon

 

Tectyl 802A Accelerated Corrosion Tests:

5% Salt Spray (Hours) ASTM** B-117 @ Recommended DFT (2x4x1/8 in. Polished Steel Panels) 96
100% Relative Humidity (Hours) ASTM D-1748 @ Recommended DFT (2x4x1/8 in. Polished Steel Panels) 1300

Tectyl 802A Surface Preparation
The maximum performance of TECTYL 802A can be achieved only when the metal surfaces to be protected are clean, dry, and free of rust, oil, and mill scale. Daubert Chemical Company recommends that the metal substrate temperature be 50 - 95F (10 - 35C) at the time of product application.

Tectyl 802A Storage
Store TECTYL 802A at temperatures between 50-95F (10-35C). Mild agitation is recommended prior to use.

Tectyl 802A Application
TECTYL 802A is formulated to be used as supplied. Ensure uniform consistency prior to use. Continued stirring is generally not required. If the product thickens due to cold storage or loss of solvent during use, contact Daubert Chemical Company. DO NOT THIN TECTYL 802A. Incorrect thinning will affect film build, dry time and product performance. Daubert Chemical Company recommends that the ambient and product temperature be 50 - 95F (10 - 35C) at time of application. TECTYL 802A can be applied by spray, slush, or dip.

Tectyl 802A Storage
Store TECTYL 802A at temperatures between 50-95F (10-35C). Mild agitation is recommended prior to use.
 
Tectyl 802A Caution
For additional handling and first aid information, refer to Dauberts Material Safety Data Sheet.

Tectyl 802A Removal
TECTYL 802A can be removed if necessary with TECTYL HPS solvent borne thinner, or lubricating oil. Avoid the use of highly aromatic solvents when removing from painted surfaces, as these solvents may adversely affect paint.